PVDF Hollow Fibers
Hinada Water Treatment Tech Co.,ltd is the professional manufacturer of water treatment UF membrane /MBR membrane/RO System/ UF plant/ MBR system for the industrial water treatment .
We can offer PVDF or PVC or PES hollow Fibers for MBR Membrane Modular and UF Membrane .
PVDF MBR Membrane Specification:
Material |
PVDF hollow fiber |
I/O diameter |
0.6/1.2mm |
Implosion pressure |
Above 2 bar |
Burst Pressure |
Above 4 bar |
Water Permeability |
10—25 L/m2. h |
Elongation at break |
About 25% |
Operating Temperature |
5℃-45℃ |
PH |
2-12 |
Operating pressure |
<0.4MPa |
Turbidity of output water |
Less than 0.2 NTU |
Filtration Method |
Suction |
Pore Size |
0.01—0.4um (Micron) |
Designation:
Accord to different input wastewater quality we suggest the design flow rate between : 10---25 L/m2. H
Permeate Water Quality:
Suspended Matter >2um, 100% removal
Organics: removal 99.99%
Turbidity of output water: ≤ 0.2NTU
SDI of output clean water: ≤ 2.5
More details information about the Hollow fibers or MBR Membrane or UF Membrane please let us know .